Water Pipeline Monitoring and Leak Detection Using Flow Liquid Meter Sensor

R F Rahmat, I S Satria, B Siregar, R Budiarto

Abstract


Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe's age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it's able to determine the leak location as close as possible with flow rate about 10 litters per minute.


Full Text: PDF

Refbacks

  • There are currently no refbacks.